346 research outputs found

    Fast, inexpensive, and reliable HPLC method to determine monomer fractions in poly(3-hydroxybutyrate-co-3-hydroxyvalerate)

    Get PDF
    The determination of the monomer fractions in polyhydroxyalkanoates is of great importance for research on microbial-produced plastic material. The development of new process designs, the validation of mathematical models, and intelligent control strategies for production depend enormously on the correctness of the analyzed monomer fractions. Most of the available detection methods focus on the determination of the monomer fractions of the homopolymer poly(3-hydroxybutyrate). Only a few can analyze the monomer content in copolymers such as poly(3-hydroxybutyrate-co-3-hydroxyvalerate), which usually require expensive measuring devices, a high preparation time or the use of environmentally harmful halogenated solvents such as chloroform or dichloromethane. This work presents a fast, simple, and inexpensive method for the analysis of poly(3-hydroxybutyrate-co-3-hydroxyvalerate) with high-performance liquid chromatography. Samples from a bioreactor experiment for the production of poly(3-hydroxybutyrate-co-3-hydroxyvalerate) with Cupriavidus necator H16 were examined regarding their monomer content using the new method and gas chromatography analysis, one of the most frequently used methods in literature. The results from our new method were validated using gas chromatography measurements and show excellent agreement. Key points ∙ The presented HPLC method is an inexpensive, fast and environmentally friendly alternative to existing methods for quantification of monomeric composition of PHBV. ∙ Validation with state of the art GC measurement exhibits excellent agreement over a broad range of PHBV monomer fractions

    Liquid hydridosilane precursor prepared from cyclopentasilane via sonication at low temperatures without the action of light

    Get PDF
    AbstractWe report on a liquid hydridosilane precursor ink prepared via the ultrasonically induced ring-opening polymerisation of cyclopentasilane (Si5H10) without irradiation by ultraviolet light. The sonication is carried out in N2 atmosphere at temperatures between 20 and 75°C. We use size exclusion chromatography (SEC) to show polymer growth and estimate molecular mass with increasing sonication time. In combination with UV–vis transmission measurements, further SEC analysis is used to compare solutions subjected to either purely thermal or ultrasonic treatment at the same process temperature and for the same duration. Our findings provide strong evidence showing that the initiation of the polymerisation is sonocatalytic in nature and not thermic due to the macroscopic temperature of the solution. The liquid precursor is used to produce homogeneous hydrogenated amorphous silicon (a-Si:H) thin films via spin coating and pyrolytic conversion. The optoelectronic properties of the films are subsequently improved by hydrogen radical treatment. Fourier transform infrared spectroscopy (FTIR) is used to determine a compact film morphology and electrical conductivity measurements show that the layers attain a light-to-dark photosensitivity ratio of 2×103 making them suitable for application in optoelectronic devices

    H-function extension of the NBD in the light of experimental data

    Get PDF
    The recently introduced H-function extension of the Negative Binomial Distribution is investigated. The analytic form of P(n) is rederived by means of the Mellin transform. Applications of the HNBD are provided using experimental data for P(n) in e+e-, e+p, inelastic pp and non-diffractive p-pbar reactions.Comment: 8 pages REVTeX, 1 eps figure embedde

    Optical Properties of Deep Ice at the South Pole - Absorption

    Get PDF
    We discuss recent measurements of the wavelength-dependent absorption coefficients in deep South Pole ice. The method uses transit time distributions of pulses from a variable-frequency laser sent between emitters and receivers embedded in the ice. At depths of 800 to 1000 m scattering is dominated by residual air bubbles, whereas absorption occurs both in ice itself and in insoluble impurities. The absorption coefficient increases approximately exponentially with wavelength in the measured interval 410 to 610 nm. At the shortest wavelength our value is about a factor 20 below previous values obtained for laboratory ice and lake ice; with increasing wavelength the discrepancy with previous measurements decreases. At around 415 to 500 nm the experimental uncertainties are small enough for us to resolve an extrinsic contribution to absorption in ice: submicron dust particles contribute by an amount that increases with depth and corresponds well with the expected increase seen near the Last Glacial Maximum in Vostok and Dome C ice cores. The laser pulse method allows remote mapping of gross structure in dust concentration as a function of depth in glacial ice.Comment: 26 pages, LaTex, Accepted for publication in Applied Optics. 9 figures, not included, available on request from [email protected]

    The AMANDA Neutrino Telescope and the Indirect Search for Dark Matter

    Get PDF
    With an effective telescope area of order 10^4 m^2, a threshold of ~50 GeV and a pointing accuracy of 2.5 degrees, the AMANDA detector represents the first of a new generation of high energy neutrino telescopes, reaching a scale envisaged over 25 years ago. We describe its performance, focussing on the capability to detect halo dark matter particles via their annihilation into neutrinos.Comment: Latex2.09, 16 pages, uses epsf.sty to place 15 postscript figures. Talk presented at the 3rd International Symposium on Sources and Detection of Dark Matter in the Universe (DM98), Santa Monica, California, Feb. 199

    Mitochondrial dysfunction in animal models of PTSD: Relationships between behavioral models, neural regions, and cellular maladaptation

    Get PDF
    Post-traumatic stress disorder (PTSD) is a trauma-related condition that produces distressing fear memory intrusions, avoidance behaviors, hyperarousal, stress responses, insomnia and other symptoms. This review of rodent models of PTSD examines trauma effects on fear-related learning, cognition, and avoidance, emotional and arousal behaviors and on mitochondrial dysfunction in relevant neural pathways. The review focuses on research that includes four elements: consensus PTSD rodent models, behavioral phenotyping, mitochondrial dysfunction within key neural regions. This approach allows for the integration of behavioral, neural and cellular findings in PTSD models. The PTSD models reviewed include fear conditioning, predator/social stress, chronic restraint stress, single prolonged stress, social isolation, chronic unpredictable stress and early life stress. These models produce a variety of PTSD-related behaviors that include associative and non-associative fear- and stress-related responses, hyperarousal, avoidance behaviors, cognitive disturbances, social withdrawal, compulsive behaviors, anhedonia-, anxiety- and depression-related behaviors. Neural regions included fear- and stress-related regions of the prefrontal cortex, hippocampal, amygdala, nucleus accumbens and hypothalamus. PTSD models produced mitochondrial dysfunction that includes dysregulation of oxidative phosphorylation and other metabolic pathways including β-oxidation of fatty acids and the tricarboxylic acid pathway. These models generated neural reactive oxygen species that damage DNA, proteins, and lipids. Trauma models further altered mitochondrial structure and replication and affected neuroinflammatory responses, signal transduction and apoptosis. Antidepressant medications used for the treatment of PTSD reversed stress-induced changes in some PTSD-like behaviors and many elements of brain mitochondrial dysfunction. Future studies can develop PTSD models which are ecologically valid and result in a broader manifestation of PTSD-related behaviors as it is clinically defined. This review highlights mitochondrial mechanisms associated with PTSD-like behaviors that have been produced in an array of consensus PTSD models and identifies putative circuit-based targets for more effective treatment for this debilitating disorder

    The AMANDA Neutrino Telescope: Principle of Operation and First Results

    Get PDF
    AMANDA is a high-energy neutrino telescope presently under construction at the geographical South Pole. In the Antarctic summer 1995/96, an array of 80 optical modules (OMs) arranged on 4 strings (AMANDA-B4) was deployed at depths between 1.5 and 2 km. In this paper we describe the design and performance of the AMANDA-B4 prototype, based on data collected between February and November 1996. Monte Carlo simulations of the detector response to down-going atmospheric muon tracks show that the global behavior of the detector is understood. We describe the data analysis method and present first results on atmospheric muon reconstruction and separation of neutrino candidates. The AMANDA array was upgraded with 216 OMs on 6 new strings in 1996/97 (AMANDA-B10), and 122 additional OMs on 3 strings in 1997/98.Comment: 36 pages, 23 figures, submitted to Astroparticle Physic

    Pre-hospital CPR and early REBOA in trauma patients-results from the ABOTrauma Registry

    Get PDF
    Publisher Copyright: © 2020 The Author(s).Background: Severely injured trauma patients suffering from traumatic cardiac arrest (TCA) and requiring cardiopulmonary resuscitation (CPR) rarely survive. The role of resuscitative endovascular balloon occlusion of the aorta (REBOA) performed early after hospital admission in patients with TCA is not well-defined. As the use of REBOA increases, there is great interest in knowing if there is a survival benefit related to the early use of REBOA after TCA. Using data from the ABOTrauma Registry, we aimed to study the role of REBOA used early after hospital admission in trauma patients who required pre-hospital CPR. Methods: Retrospective and prospective data on the use of REBOA were collected from the ABOTrauma Registry from 11 centers in seven countries globally between 2014 and 2019. In all patients with pre-hospital TCA, the predicted probability of survival, calculated with the Revised Injury Severity Classification II (RISC II), was compared with the observed survival rate. Results: Of 213 patients in the ABOTrauma Registry, 26 patients (12.2%) who had received pre-hospital CPR were identified. The median (range) Injury Severity Score (ISS) was 45.5 (25-75). Fourteen patients (54%) had been admitted to the hospital with ongoing CPR. Nine patients (35%) died within the first 24 h, while seventeen patients (65%) survived post 24 h. The survival rate to hospital discharge was 27% (n = 7). The predicted mortality using the RISC II was 0.977 (25 out of 26). The observed mortality (19 out of 26) was significantly lower than the predicted mortality (p = 0.049). Patients not responding to REBOA were more likely to die. Only one (10%) out of 10 non-responders survived. The survival rate in the 16 patients responding to REBOA was 37.5% (n = 6). REBOA with a median (range) duration of 45 (8-70) minutes significantly increases blood pressure from the median (range) 56.5 (0-147) to 90 (0-200) mmHg. Conclusions: Mortality in patients suffering from TCA and receiving REBOA early after hospital admission is significantly lower than predicted by the RISC II. REBOA may improve survival after TCA. The use of REBOA in these patients should be further investigated.Peer reviewe

    The AMANDA Neutrino Telescope

    Full text link
    With an effective telescope area of order 10410^4 m2^2 for TeV neutrinos, a threshold near ∼\sim50 GeV and a pointing accuracy of 2.5 degrees per muon track, the AMANDA detector represents the first of a new generation of high energy neutrino telescopes, reaching a scale envisaged over 25 years ago. We describe early results on the calibration of natural deep ice as a particle detector as well as on AMANDA's performance as a neutrino telescope.Comment: 12 pages, Latex2.09, uses espcrc2.sty and epsf.sty, 13 postscript files included. Talk presented at the 18th International Conference on Neutrino Physics and Astrophysics (Neutrino 98), Takayama, Japan, June 199
    • …
    corecore